A bigger cam closes the intake valve later, which bleeds off cylinder pressure, so it needs more static compression to keep the same dynamic compression. This chart gives the static ratio each cam needs to reach a target dynamic ratio.
On pump gas, iron heads run about 8.2:1 dynamic on 91 and 8.4:1 on 93; aluminum heads about 9.3 and 9.7. For your own engine, use the compression ratio calculator.
| Intake duration @ .050" | Intake centerline | For 7.5:1 dynamic | For 8.0:1 dynamic | For 8.5:1 dynamic | For 9.0:1 dynamic |
|---|---|---|---|---|---|
| 200° | 112° | 8.4:1 | 8.9:1 | 9.5:1 | 10.1:1 |
| 204° | 112° | 8.5:1 | 9.0:1 | 9.6:1 | 10.2:1 |
| 208° | 112° | 8.5:1 | 9.1:1 | 9.7:1 | 10.3:1 |
| 212° | 110° | 8.5:1 | 9.1:1 | 9.7:1 | 10.3:1 |
| 216° | 110° | 8.6:1 | 9.2:1 | 9.8:1 | 10.4:1 |
| 220° | 108° | 8.6:1 | 9.2:1 | 9.8:1 | 10.4:1 |
| 224° | 108° | 8.7:1 | 9.3:1 | 9.9:1 | 10.5:1 |
| 228° | 108° | 8.9:1 | 9.5:1 | 10.1:1 | 10.7:1 |
| 232° | 106° | 8.9:1 | 9.5:1 | 10.1:1 | 10.7:1 |
| 236° | 106° | 9.0:1 | 9.6:1 | 10.2:1 | 10.8:1 |
| 240° | 106° | 9.1:1 | 9.7:1 | 10.4:1 | 11.0:1 |
| 244° | 106° | 9.2:1 | 9.9:1 | 10.5:1 | 11.1:1 |
| 248° | 106° | 9.4:1 | 10.0:1 | 10.7:1 | 11.3:1 |
| 252° | 106° | 9.5:1 | 10.2:1 | 10.9:1 | 11.5:1 |
| 256° | 106° | 9.7:1 | 10.4:1 | 11.0:1 | 11.7:1 |
| 260° | 106° | 9.9:1 | 10.6:1 | 11.2:1 | 11.9:1 |
| 264° | 106° | 10.1:1 | 10.8:1 | 11.5:1 | 12.1:1 |
| 268° | 106° | 10.3:1 | 11.0:1 | 11.7:1 | 12.4:1 |
350 small-block Chevy (4.00" bore, 3.48" stroke, 5.7" rod). Effective intake closing = the .050" closing + 15°, the compression calculator's method. Centerlines step from 112° on small cams to 106° on race cams, as cams are commonly ground; installing a cam advanced lowers the static ratio needed a little.
| Fuel | Iron heads: most dynamic CR | Aluminum heads: most dynamic CR |
|---|---|---|
| 87 octane | 7.60:1 | 8.70:1 |
| 91 octane | 8.15:1 | 9.35:1 |
| 93 octane | 8.45:1 | 9.70:1 |
| 100 race fuel | 9.50:1 | 10.90:1 |
Our estimate from a knock model fitted to published pump-gas builds, the same limits as the compression calculator: sea level, about 32° total timing, no knock sensor.
Octane by static ratio and cam: compression ratio and octane chart.